Notes : |
Per Kodak tech support, interface consists of a NULL MODEM cable. The following Modes must be set in the 310:
03 AutoPrint = on
04 Auto Time = off
11 Technet print format
12 300 baud ( or 13, 1200 baud)
15 Advanced Technet filter mode
19 Shortened printout (no channel data)
21 Data format of #########
vxxx<sp>rxxx<sp>gxxx<sp>bxxx<sp><cr><lf>
Also note, the 310 ties pin 4 (DSR) and 5 (CTS/BUSY) inputs together. In print mode, the 310 expects BUSY to be LOW. In Technet mode, CTS must be HIGH, driven by RTS from host. |